Our Products > CLEANROOM SYS. PRODUCTS > Hepa Filter Housing
CLEANROOM SYS. PRODUCTS
Laminar Flow Cabins
Hepa Filter Housing
Suction Ducts With Leaf Filter Unit
Leaf Filter Unit
Hygienic Air Diffuser
Laminar Flow Units For Operating Theatres
Pressure Control System Panel for Cleanrooms
U-Manometer
Duct Leakage Test Kit
AIR-CONDITIONING SYS. PRODUCTS
Aluminium Air Louvers
Aluminium Damper
Sound Attenuators
G3-G4 Filters and Frames
Deflektors and Seperators
TEXTILE AIR-COND. SYS. PRODUCTS
Rotary Drum Filter
Rotary Pre-Filter
Cyclone Seperator and Compactor
Prefilter
Industrial Type Axial Fan
Inspection Door
Nozzles For Airwasher Applications
Service Door
Deflectors and Seperators
AIR-CONDITIONING SYSTEMS
Hygienic Air-Conditioning Systems
Industrial Air-Conditioning System
Textile Air-Conditioning Systems
MEASUREMENT PRODUCTS
Volume Measuring Sensor
Indication Panel for Control of Hepa Filters
Pressure Control System Panel for Cleanrooms
U-Manometer
Duct Leakage Test Kit
REPRESENTATIONS
 
 

> Hepa Filter Housing

 
 

 

HEPA FILTER HOUSING

Main demands of the clean room technology and especially in its pharmaceutical applications is the air-conditioning and also accordingly the air quality. Air distribution is generally made through the HEPA filter installed to its housing. Therefore, selection and assembling the HEPA filter to its housing

without leakage is very important. Tetisan HEPA Filter Housing consists of 3 main parts, which are the box, filter and the diffuser. Box has a duct connection port for air inlet at the top or at the sides. On the room side the diffuser can be selected either with special vanes adapted to cleanrooms or with a perforated plate. Filters can be chosen according to the room Class from EU10 to EU16. HEPA Filter Boxes weighs between 12 kg and 47 kg according to the construction type. All HEPA Filter boxes are tested for leakages with test groove system.

 

To track filter working conditions, HEPA boxes have nozzles for differential manometer connections. According to the EN 1882 standards, boxes have nozzles for supplying test aerosols (DOP). Test grooves that face the HEPA filter gasket achieves air tightness according to DIN 1946 Part 4. Inside of

the housing can be easily disinfected and will not be effected from disinfection chemicals.

 

Hepa Filter Box

Hepa Filter

Perforated Diffuser

Width
mm

Length
mm

Height
mm

Width
mm

Length
mm

Height
mm

Width
mm

Length
mm

322

322

350

305

305

75

350

350

474

474

400

457

457

75

500

500

627

627

400

610

610

75

650

650


 

 

 

 


Geri Dön
 
Top of Page
Search In Site  
Join Mailing List  
Tetisan Endüstriyel Klima    |    Tunç Cad. Has Sanayi Sitesi, A Blok 34538 Bahçeşehir, İstanbul TURKEY    |    Tel: +90212 6232015     Fax: +90212 6232017