Our Products > CLEANROOM SYS. PRODUCTS > Laminar Flow Units For Operating Theatres
CLEANROOM SYS. PRODUCTS
Laminar Flow Cabins
Hepa Filter Housing
Suction Ducts With Leaf Filter Unit
Leaf Filter Unit
Hygienic Air Diffuser
Laminar Flow Units For Operating Theatres
Pressure Control System Panel for Cleanrooms
U-Manometer
Duct Leakage Test Kit
AIR-CONDITIONING SYS. PRODUCTS
Aluminium Air Louvers
Aluminium Damper
Sound Attenuators
G3-G4 Filters and Frames
Deflektors and Seperators
TEXTILE AIR-COND. SYS. PRODUCTS
Rotary Drum Filter
Rotary Pre-Filter
Cyclone Seperator and Compactor
Prefilter
Industrial Type Axial Fan
Inspection Door
Nozzles For Airwasher Applications
Service Door
Deflectors and Seperators
AIR-CONDITIONING SYSTEMS
Hygienic Air-Conditioning Systems
Industrial Air-Conditioning System
Textile Air-Conditioning Systems
MEASUREMENT PRODUCTS
Volume Measuring Sensor
Indication Panel for Control of Hepa Filters
Pressure Control System Panel for Cleanrooms
U-Manometer
Duct Leakage Test Kit
REPRESENTATIONS
 
 

LAMINAR FLOW UNITS FOR OPERATING THEATRES

- Montage and service friendly with high tech design.

- DIN 4799 Standart sterility on partial and full capacities.

- HEPA Filter Box with differential manometer connection probes.

- Pendant Lamp connection detail.

- H13 / H14 Filters individual test certificated according to EN 1822 standards, (%99,95 / %99,995 at MPPS efficiencies). Aluminum frame (connection side with gasket, other side with face guard).

Operation theatre type Laminar Flow Unites are used to supply laminar flow over the operating table and its perimeter. Laminar Flow Unites prevent operating zone from microbes, bacteria and other living organisms.

Operation theatre type Laminar Flow Units are constructed from stainless steel. For filtration H13 / H14 HEPA filters with aluminum frames are used. A laminisator made of special taut silk fabric is used under the laminar flow unite, to achieve laminar flow. Laminisator is made of two parts with a special design that enables pendant lamp connection in the middle of the unit.

In Laminar flow unites for operation theatre applications, face velocity is taken between 0,2-0,3 m/s. Larger velocities from 0,3 m/s cause draught affect on people under the unite, on the other hand velocities smaller than 0,2 m/s cause deformations in laminar flow. 
 

LAMINAR FLOW UNITS FOR OPERATING THEATRES

Product Code

W
mm

L
mm

H
mm

Surface Velocity

Flow

HEPA Filter

Pressure Losses

Min.
 (m/s)

Maks.
(m/s)

Min.
 (m³/s)

Maks.
(m³/s)

Model
(H14 Optional)

Qu

Initial
Pa

Final
Pa

LAF

12

x

24

1200

2400

450

0,2

0,3

2.074

3.110

HC-H13-AN-305x610-FC

2

250

600

LAF

14

x

24

1400

2400

450

0,2

0,3

2.419

3.629

HC-H13-AN-305x610-FC

2

250

600

LAF

16

x

24

1600

2400

450

0,2

0,3

2.765

4.147

HC-H13-AN-305x610-FC

2

250

600

LAF

18

x

24

1800

2400

450

0,2

0,3

3.110

4.666

HC-H13-AN-305x610-FC

4

250

600

LAF

24

x

24

2400

2400

450

0,2

0,3

4.147

6.221

HC-H13-AN-305x610-FC

4

250

600

LAF

18

x

30

1800

3000

450

0,2

0,3

3.888

5.832

HC-H13-AN-305x610-FC

4

250

600

LAF

24

x

30

2400

3000

450

0,2

0,3

5.184

7.776

HC-H13-AN-305x610-FC

4

250

600


 


Geri Dön
 
Top of Page
Search In Site  
Join Mailing List  
Tetisan Endüstriyel Klima    |    Tunç Cad. Has Sanayi Sitesi, A Blok 34538 Bahçeşehir, İstanbul TURKEY    |    Tel: +90212 6232015     Fax: +90212 6232017